Found Stencil cleaning agent more consumption then usual, so we found the root cause, pipe leakage and replaced.
Before: We Have analyzed that past few days, we have using chemical for stencil cleaning more than necessary in our machine. When we checked the root cause of this found pipe leakage in machine.
After: So, we fixed the leakage issue by changing the pipe and follow up the consumption, found standard.
04-08-2025
21-08-2025
Productivity
HOD oKby : Ankur Sharma
KPO: Okby : Jyoti Prasad Mallick
CI: okby : Shubham Srivastava