Kaizen
Back
As we have received high rejection for P-Sensor in which sensor sleeve shifted issue observed so we have modified the process for improvement. Model:- Shark 5G
In which previously PCBA fitment process on going from top to bottom so sensor sleeve is getting shifted.
Now we have modified the process of PCBA fitment in which PCBA fitment process will be bottom to top. also updated in SOP.
01-07-2025
12-07-2025
Quality
HOD Good Kaizenby : Ajay Rawat
KPO: okby : Sandip Kumar Kushwaha
CI: okby : Shubham Srivastava