Power key hard not detected at single time for Ft because we have observed market failure and OQA failure for key hard issue in all smart phone.
During observed FT test stage power key hard checking for charging test stage but after back cover pressing then observed at OQA and market for Power key hard issue in smart phone!
After observed power key hard issue not detected in after FT process so add to check point at Power off and TPU Cover removed after FT. to check power key hard and lose with 2 times then power off and removed TPU cover after RF stage.
25-06-2025
05-07-2025
Quality
HOD SOP updated for same. Process optimized as checkpoint added onlineby : Ajay Rawat
KPO: okby : utkersh mishra
CI: okby : Shubham Srivastava