Kaizen
Back
Improvement in Yuva2 5G TP/LCD for key holder fall off issue
Key holder fall off issue reported in Yuva2 5G at production line in first 500 trial parts. Cause:- The C46 dimension of the midframe is at the upper limit of 2.23mm (specification requirement is 2.18 ± 0.05mm for PVT materials).
To avoid the key holder fall off issue supplier has adjusted the tolerance Range of midframe to 2.18 + 0.03mm,-0.05mm to reduce the gap in extreme cases that facing in PVT.
01-01-2025
08-01-2025
Quality
HOD okby : Amit Kumar
KPO: okayby : Amit Kumar
CI: okby :