Earlier torch pad have less solder due to this torch key failure in Assembly.
Now we have modified the stencil by step up design to 0.47 mils by which we have reduced the both failure. before-0.02% after-0.01%
07-11-2024
08-11-2024
Quality
HOD okby : Sunil kumar
KPO: okby : Jai Prakash Singh
CI: okby :