Kaizen Description

RF Fail coming in high Qty in Model A3 Torch During NPI. RF fail coming during NPI at RF Test Stage , After analysis found Pin uplift and poor connectivity issue coming from Antenna Pressing Machine. due to this, devices were coming fail during RF Test. Now Improvement done in Antenna Pressing Machine and re-pressing done in All Devices after that passed all Devices and no issue coming during RF Test

Before Situation

RF Fail coming in high Qty in Model A3 Torch During NPI. RF fail coming during NPI at RF Test Stage , After analysis found Pin uplift and poor connectivity issue coming from Antenna Pressing Machine. due to this, devices were coming fail during RF Test.

After Situation

Now Improvement done in Antenna Pressing Machine and re-pressing done in All Devices after that passed all Devices and no issue coming during RF Test