Kaizen

Back

HOD ok
by : Vipin Kumar

KPO: Approved
by : Jyoti Prasad Mallick

CI: ok
by : Aman sharma

Team Member - 1
Team Member - 2
HOD
KPO
CI Team
Finance
Kaizen Theme
Kaizen Description

Line-4 Post AOI Running time fiducial out

Before Situation

The post AOI of Line-4 to be fiducial out in the running line. the ball screw of the head is causing problem. due to which fiducial error would occur every once in a while.

After Situation

After, then we fixed the IR Sensor by moving it a little back from where it was fixed and the machine went under observation. then there was no problem in the machine. machine running continusoly running ok.

Kaizen Start Date

13-05-2024

Kaizen End Date

16-05-2024

Result

Productivity

Cost Calculation Sheet
Improvement Details