Dust Issue in Lava Gem power Model at router machine cutting stage.
Before:- At router stage in cutting points of model Lava Gem power dust issue is coming and it is reported at cutting position near connector. The operator use to clean by brush.
After:- Now we fix double side tape near to cutting point in router zig in rectangular way that will not effect other components. By this implementation dust issue is controlled
06-05-2024
08-05-2024
Productivity
HOD okby : Vipin Kumar
KPO: Approvedby : Jyoti Prasad Mallick
CI: okby : Aman sharma