| Before Situation |
1:- These all handest were failed in FT for Display white/flickering/dot issue.
2:- After CFT analysis found these are from incoming side issue , but IQC team has denied to accept them in vendor bucket.
3:- LCD pad damage defects has entred in process bucket, but still defect generation was not conclsued after multple trail.
Last 3 motnhs LCD Rejection Data-
A5_23 - 1.37%
A7 Torch - 1.03%
> This issue comes from incoming side also not visual by nacked eye.
> High rejection observed from incoming but due to denied by IQC team each defect punched in process. |
|
|
| After Situation |
"1. Now after production meeting discussion, only sorting material will provide on line.
2. IQC Team will do 100% LCD soring , after LCD on and check fleckering and white issue.
3. After sorting , main line LCD rejection will check. " |
|
|