Kaizen

Back

HOD OK
by :

KPO: ok
by :

CI: ok
by :

Team Member - 1
Team Member - 2
HOD
KPO
CI Team
Finance
Kaizen Theme
Kaizen Description

separate work into two different stage at FT side in Model- Yuva 2 Pro. At charging test stage need to done only charger and volume key not "Power Key" and "Power Key" need to check at next stage "Loop back "stage. "Due to same manpower listen clear speaker sound at which he will work and rest handset is on normal mode."

Before Situation

At present time Charging test stage ,manpower do charger test with also volume up ,down & power key due to which all 4 handset speaker is ON mode and then tray move to next stage "Loopback Test "stage at which all 4 handset speaker is working as well as creates Noise at that stage . So that manpower not listen clear sound at loopback stage ,its may be lead to bypass of speaker sound not Ok issue .

After Situation

After process divide, at loopback stage manpower only listen sound at which they work and rest handset is normal/silent mode .So that manpower listen clear sound and there is no chance of speaker not ok handset bypass from them.

Kaizen Start Date

01-03-2023

Kaizen End Date

04-03-2023

Result

Productivity

Cost Calculation Sheet
Improvement Details