Front Camera fail issue in model:- E13

Before Situation

1. The voltage drop of the 15th pin of the abnormal image opening module is 0Ω, the voltage drop of the 26th pin is 0.107Ω, and the voltage drop of the same pin of the normal image opening module is 0.344Ω 0.336Ω respectively, which is obviously different. 2. After analysis it is observed that there was invisible damage to the internal circuit of the circuit board, which leads to abnormal current transmission and makes the image unable to be opened.

After Situation

1. Based on the above situation, the reason of module opening NG is that the internal circuit of the circuit board is damaged, which leads to abnormal current transmission and makes the image unable to be opened. 2. In view of the possible risk of camera module failure during transportation, a vibration procedure is added to the process test process to stimulate the internal damage of FPC generated during transportation in advance.