Kaizen Description |
No power issue come in assembly due to SW not done 100% , operator remove the pcb before completion the SW due to confusion in sw done and not done identification . now we have remove the auto pulling system and provide color identification after SW 100% done . After SW done yellow color highlighted in system . |
|
|