Kaizen
Back
Earlier in FP, torch test and headphone test both was performed on same stage so that operator some time not detect torch fail handset .Now torch test performed separately in FT sequence to ensure torch is must be worked.
Earlier in FP torch test and headphone test both was performed on same stage so that operator some time not detect torch fail handset
Now in FP like-A1 Josh with BOL, torch test performed separately in FT sequence to ensure torch is must be worked.
04-12-2023
11-12-2023
Quality
HOD OKby :
KPO: OKby :
CI: okby :