Reduction of Flashlight failure in SP
Previously we have checked the flashlight in dark box (Flashlight is back side) , One time 2 device was checked so there is chance to skip the flashlight failure from FT
We have implemented new process with PCR to checked the device after rotation (flash light will be on front side) in dark box
07-12-2023
08-12-2023
Quality
HOD okby :
KPO: okby :
CI: okby :