Kaizen Star - Plant 1
Aakash Reddu
April - 2024
Total1
| Sr. No | Kaizen No | Kaizen Theme | Initiator | Team | Before Situation |
After Situation |
Month | ||
| 1 | LCIK - 41275 |
Process improvement. |
Sanket , 51009008 |
Shubham , 51009029 Yashbir , 51008101 |
All EOL model stencil and tolling was placed on shop floor and mixed up with running model so there was chances to load wrong tolling or stencil on line because of we have similar model name . | We make a list of EOL model and seperate all stencil and tolling and move to ground floor smt store. | 08/2024 | ||
| 2 | LCIK - 41276 |
Process improvement. |
Yashbir , 51008101 |
Brajesh , 51009217 Sanket , 51009008 |
featured in mounter direct lighting deployed for recognition so there was droppage and failure of MIC up-side down at pre AOI. | Now we have deployed shadow lighting feature for recognition and brightness check feature also deployed for Up-side down and validated the failure control. | 08/2024 | ||
| 3 | LCIK - 41288 |
Process improvement. |
Shubham chand boudai , 51010132 |
Yashbir , 51008101 , 51009929 |
BTB connector attached with pcb and this pcb mount on main pcb . no body mark or special mark on body for polarity detection. only a side cut on one corner on the pcb . | At aoi we use 3d height detection on this corner cut of connector for polarity detection . | 08/2024 | ||