** ***** Give Kaizen on Theme - Near Miss & win exciting prizes ! *****

Kaizen Corner

Sr. No Kaizen No Kaizen Theme Initiator Team Before
Situation
After
Situation
Month
1 LCIK - 39143
Productivity Improvement
Rohit kumar ray , 51009727
Krishna Puri , 166868
In Chiller of all reflow oven we could not measure low level and high level of DI water due to that in case of low level reflow oven starts giving alarm and result reflow operation effected. we define high and low level stciker for DI water so that we can check the measurement and can fill it before it reach low level. In this way we maintain the issue and it improve process and no loss effect to production. 11/2023
2 LCIK - 41703
Productivity Improvement
Jaydeep Chaturvedi , 51009711
At RF sage mostly PC ports get blocked due to which PC was restarted or it get changed. This process of troubleshooting consume more time due to which it impact on production. We have tried by installing the USB hub in OK ports it work as multiple ports and RF PV working fine after doing ports. due to which no loss will occurred. 10/2024
3 LCIK - 39403
Productivity Improvement
Sanket , 51009008
Brajesh , 51009217
Shubham chand boudai , 51010132
Previously we are facing solder ball and sim connector uplift issue due to pallet not open on sim card through-hole location. Now we modify the pallet on sim connector through-hole location so temp. properly reached at sim connector so uplift issue and solder ball issue resolved . One week continue observed but we cant face such issue repeatedly. 12/2023