Kaizen Star - Plant 1
Aakash Reddu
April - 2024
Total1
| Sr. No | Kaizen No | Kaizen Theme | Initiator | Team | Before Situation |
After Situation |
Month | ||
| 1 | LCIK - 43760 |
Quality |
Krishna Kumar Singh , 51010395 |
Before more PCBA was blast on pre loader test due to shorting in IC and PCBA. Due to this more PCBA become useless as well as to become blast of PCBA more chances to incident of concern operators. | Now we have apply the electric bulb in loader tester . For doing this when any shorting come in PCBA electric bulb glow as well as no any chances to blast the charger . | 02/2026 | |||
| 2 | LCIK - 43761 |
Quality |
Krishna Kumar Singh , 51010395 |
Before there was no any control to catch the wrong pallet stop to going in WSM machine . Due to this there was more shorting comes in PCB panel. | Now we apply the sensor end of MI conveyor to stop the wrong PCB Panel. For doing this we save our PCB to shorting. | 02/2026 | |||
| 3 | LCIK - 42227 |
quality |
Pankaj Tiwari , 51010434 |
Lava Shark model has a point of screen guard bubble at ABC stage due to which ABC miss match problem was occurring during ABC. Due to which our lot is on hold. | Added one failure point in IMES in repair packing for bubble in any device we fail that device and run from input stage. Updated in packing learning sheet. | 03/2025 | |||