Kaizen Star - Plant 1
Aakash Reddu
April - 2024
Total1
| Sr. No | Kaizen No | Kaizen Theme | Initiator | Team | Before Situation |
After Situation |
Month | ||
| 1 | LCIK - 37810 |
Quality enhancement |
lokesh kumar , 51009193 |
Flash fail skip issue came in OQA operator could't detect at testing time | Dark room has been increased at stage of flash test to avoid same . | 01/2023 | |||
| 2 | LCIK - 40254 |
Quality and productivity improvement |
Yashbir , 51008101 |
When we made new data of Random ball BGA part during the NPI then we select the body size then given random ball to detect the mounter so some time machine not adjust the placement according to body size and part had to shift & skew during mounting time. | Now we select the only random ball area size and also select its center ball to reference the mounting placement during create new data.,after doing this activity no issue reported at Pre AOI for BGA part shifting and skew issue . | 04/2024 | |||
| 3 | LCIK - 41037 |
Quality and productivity improvement |
Akhilesh yadav , 51008584 |
, 51009929 Sanket , 51009008 |
In the air ionizer we are using stand to hold the air unit. Sometimes it getting loose from the screw and the air automatically getting on. during this extra wastage of air. | We are using modified stand in air ionizer. And now not any kind of air wastage.it turn on when the board available on the sensor only. | 07/2024 | ||
| Previous 579 580 581 582 583 Next | |||||||||