1 LCIK - 41706
Quality improvement
Krishna Kumar Singh , 51010395
Earlier We are using AIR ionizer to clean the router cutting dust due to this we are facing MIC foam damage issue .. Now we using ESD brass only to clean the router cutting dust ..after this control foam damage issue. 10/2024
2 LCIK - 42218
Quality improvement
Priyamjit Paul , 51009135
Earlier we were facing high P sensor failures issue ,2.0 % In Model- Blaze X MB. Now we have increased the stencil aperture from 4.5 mil to 8.5 mil for increase the solder at the PCBA Pad,After that failure controlled. 02/2025
3 LCIK - 36843
Quality improvement
Man Singh , 51009389
Dinesh Kumar , 51009095
, 51009055