** ***** Give Kaizen on Theme - Near Miss & win exciting prizes ! *****

Kaizen Corner

Sr. No Kaizen No Kaizen Theme Initiator Team Before
Situation
After
Situation
Month
1 LCIK - 42216
Quality improvement
Sumit Kumar Maurya , 59428
Before we have faced 5% rejection rf calibration flag down issue in yuva2_5g , which have no detection in smt at any stage. Now at rf stage the after every GSM ,LTE,NR test the tool will validate the flag status after that no rejection found in assembly 02/2025
2 LCIK - 37865
Quality improvement
Jitendra kumar , 44087
SURAJ KUMAR , 44257
Rohit Prasad , 166428
02/2023
3 LCIK - 42217
Quality improvement
Priyamjit Paul , 51009135
RF Fail coming in high Qty in Model A3 Torch During NPI. RF fail coming during NPI at RF Test Stage , After analysis found Pin uplift and poor connectivity issue coming from Antenna Pressing Machine. due to this, devices were coming fail during RF Test. Now Improvement done in Antenna Pressing Machine and re-pressing done in All Devices after that passed all Devices and no issue coming during RF Test. 02/2025
 Previous  568  569  570  571  572 Next