1 LCIK - 42091
Quality Improvement
Krishna Kumar Singh , 51010395
Before there are more and maximum solder ball and vinayal present under the conveyor . Due to this maximum time defect has come. Now at this to solve this issue we run the vacuum cleaner on line according to our schedules so that vinayal and solder ball will finish forever . In present time solder ball and vinayal has finished as well as defect is not coming related with solder ball and vinayal . It means that defect has finished . 01/2025
2 LCIK - 42859
Quality improvement
Sumit Kumar Maurya , 59428
In Yuva 5G model scratches and dent cases are more coming ,there is a probability of dent due to data cable of metal used . Now in this model to remove this type issue plastic data cable is used and this issue is terminate. 08/2025
3 LCIK - 42860
Quality improvement
Sumit Kumar Maurya , 59428
P Sensor Dry soldering due less solder in the pad, paste at the pcba pad not getting melt properly and making contact with the part. Now we have increased 3 mils in both length & width of stencil aperture by this issue has been eliminated . 08/2025