Kaizen Star - Plant 1
Aakash Reddu
April - 2024
Total1
Sr. No | Kaizen No | Kaizen Theme | Initiator | Team | Before Situation |
After Situation |
Month | ||
1 | LCIK - 41787 |
Quality improvement |
Kapil Kumar , 51010568 |
If we have return to MRN used PCBA then that time if doing proper els with checked binding issue and also to know that where is found this PCBA and which stage, and also check why doing Mrn. | If we have done the uper activity on daily basis then safe the so many problem on line which create that running on line MRN Part. | 11/2024 | |||
2 | LCIK - 41788 |
Quality improvement |
Kapil Kumar , 51010568 |
Before We are using Z Tcode in SAP PCBA moved After Physical scanning by PQC and after receiving in SMT they will accept In SAP. and this process is taking time | Now we have Changed the process in which PQc is sharing Detail on requisition Slip after Physical validation mc is sharing Document number after Posting . PCBA movement is allow only after Posting. | 11/2024 | |||
3 | LCIK - 41533 |
Quality improvement |
, 51010562 |
RF Fail coming in high Qty in Model A3 Torch During NPI. RF fail coming during NPI at RF Test Stage , After analysis found Pin uplift and poor connectivity issue coming from Antenna Pressing Machine. due to this, devices were coming fail during RF Test. | Now Improvement done in Antenna Pressing Machine and re-pressing done in All Devices after that passed all Devices and no issue coming during RF Test. | 09/2024 | |||
Previous 389 390 391 392 393 Next |