1 | LCIK - 41416 |
Reduce the P Sensor failures. |
Raj kamal yadav , 51008653 |
Rohit dwivedi , 51008107 Kartik Rautela , 55955 |
Earlier we were facing high P sensor failures issue ,2.0 % In Model- Blaze X MB. | Now we have increased the stencil aperture from 4.5 mil to 8.5 mil for increase the solder at the PCBA Pad,After that failure controlled. | 08/2024 | ||
2 | LCIK - 38014 |
![]() Reduce Test time in N31 Audio Tool |
SANJAY RUPANI , 51009511 |
Anuj Kumar Yadav , 51008899 Saba Anwar , 51009386 |
Earlier, when the speaker test failed in neckband audio testing,tool used to check other parameters as well, due to which the testing time increased. | Later we added an option to test in sequence, which will stop the test if any parameter fail, due to which reduced our test cycle time. | 02/2023 | ||
3 | LCIK - 39261 |
![]() Reduce Test time in N11 Audio Tool |
SANJAY RUPANI , 51009511 |
Anuj Kumar Yadav , 51008899 Saba Anwar , 51009386 |
Earlier in neckband audio testing, if the speaker test failed, the tool was used to check other parameters also, which increased the testing time. | Later we added an option to test in sequence, which would stop testing if any parameter failed, which reduced our testing cycle time. | 12/2023 | ||