1 LCIK - 38311
Torch test sequence removed from Auto test mode
Pawan Kumar , 51009498
Abhin Manra , 51009366
Gange Naresh , 51009421
In before situation , Torch started glowing after entering in FT mode so we can check Torch but still torch test process was added in auto test in below software version:-LAVA_A3_032_024_V1.0_M010_20230221_ENG_IN In after situation, Torch test removed from auto test, in this case operator will check in starting of FT test mode . Software version:-LAVA_A3_032_024_V1.0_M011_20230228_ENG_IN 03/2023
2 LCIK - 40811
Torch failure in Assembly line
Rohit dwivedi , 51008107
Kartik Rautela , 55955
Raj kamal yadav , 51008653
Earlier torch pad have less solder due to this torch key failure in Assembly. Now we have modified the stencil by step up design to 0.47 mils by which we have reduced the both failure. before-0.02% after-0.01% 06/2024
3 LCIK - 40718
Top side scratch impression mark failure improvement
ANKIT KUMAR , 166875